Coway Airmega 100 · White
Match the Airmega 100 model and the documented filter. Use the room-fit worksheet rather than a retailer’s headline area claim.
ROOM STUDY 03 / OUTLET MEASUREMENTS
Compare two meter readings even when they cover different lengths of time. Use one sample for a quick estimate, or add a second to compare schedules.
The starting figures are a worked example, not test results or a quote. Replace them with your meter readings and electricity rate.
Use the kWh accumulated during each sample and the elapsed time for that same sample, including any idle time you want represented.
NORMALIZED TO 24 HOURS
| Estimate | Sample A | Sample B |
|---|---|---|
| Daily energy | 0.42 kWh | 0.27 kWh |
| Average draw | 17.5 W | 11.25 W |
| Annual energy | 153.3 kWh | 98.55 kWh |
| Annual cost | $30.66 | $19.71 |
| 3-year cost | $91.98 | $59.13 |
Sample B uses 54.75 kWh less per year in this projection.
Projections assume the sample pattern repeats for 365 days each year. Costs cover electricity only. A lower reading doesn’t establish equal smoke CADR or room coverage.
Follow the meter and purifier manuals and stay within their electrical ratings. Start each log with a known initial kWh value and record the difference after a representative period. Include any overnight mode, idle time or automatic speed changes that are part of the routine you want to compare.
Divide kWh by elapsed hours and multiply by 24 for daily energy. If the purifier uses Auto mode or the room schedule changes, log representative days before treating a short measurement as typical.
References: U.S. Department of Energy: electricity and kWh · P3 P4400 meter manual (PDF)
Change the tool inputs to see relevant references. Compatibility remains a separate check.
As an Amazon Associate I earn from qualifying purchases. These are optional references, not product tests or live offers.
Match the Airmega 100 model and the documented filter. Use the room-fit worksheet rather than a retailer’s headline area claim.
A separate Airmega model and filter family. Check the exact regional label before using the documented room-fit figures.
The 250 model, separate from the 250S Wi-Fi version. Check the matching filter and the source notes in the room-fit catalogue.
Keep 311i Max separate from 311i+ Max and older 311 models when choosing a replacement filter.
The Coway-branded Max2 filter set documented for Airmega 250 and 250S. Match the appliance label and package code; this is separate from the washable pre-filter.
A US outlet energy meter for the power worksheet. Check electrical limits; measured watts are not smoke CADR or proof of purification.
A humidity and temperature reference for checking a room while using moisture-control equipment. Check placement and Bluetooth range; it does not measure airborne particles or CO.
A top-fill ultrasonic humidifier for adding moisture. Follow the water-quality and cleaning instructions and monitor room humidity; it is not an air purifier.
The single-pack battery-operated SMI100, separate from the hardwired SMI100-AC. Check local requirements and alarm testing instructions; this model is not a CO alarm.
A battery-operated carbon monoxide alarm. It is not a smoke alarm or a carbon-dioxide meter; check the exact local model and placement instructions.
The battery-operated SMCO100 combination alarm. Check local requirements and the manufacturer’s placement and testing instructions; an air-quality monitor does not replace it.
A CO₂, temperature, humidity and pressure monitor for following room conditions. CO₂ readings are not smoke CADR and this is not a carbon-monoxide alarm.
Room planner · Check exact filter codes · Particle and gas limits